Boddingtons Electrical Insulating Flex & Grip Natural Rubber Safety Gloves, 17000 Max Working Voltage, Class 2, Length 410mm, Thickness 3.1mm, Category RC, with Outer Coating in Orange and Red Elastomer, Size 7

Not rated yet

Natural rubber gloves with outer coating in orange red elastomer, black interior, cut edges. Special proper ties (category) RC, with mechanical protection. Gloves with reinforced mechanical protection: no need any leather over gloves. Product made with a high-performance polymer blend that combines mechanical, chemical and dielectric resistances. Specially formulated outer coating that provides exceptional grip, even in humid or greasy conditions. Complete range : from class 00 to class 4. 

  • The unique formulation of the rubber compound makes Flex & Grip gloves extremely flexible. 
  • Each pair of composite gloves is supplied with one pair of cotton fingerless under gloves to improve comfort; it’s recommended to replace regularly the cotton gloves for hygienic reasons.
  • Composite insulating gloves with integrated mechanical protection and arc flash rating

Testing

Gloves are tested and certified to EN 60903 and IEC 60903

No gloves of classes 1, 2, 3 and 4, not even those held in storage, should be use unless they have been tested within a maximum period of 6 months. . However they do need testing every six months. The tests should include air inflation to check for leaks (using our pneumatic glove tester), a visual inspection while pressurized and a dielectric test in accordance with EN60903 standards of live working gloves of insulating material.

From the annex E (informative) of the EN-60903 standard 

Typical Industries

  • Automotive
  • Electronics
  • Logistics and Warehousing
  • Machinery and Equipment
  • Mining
  • Public Utilities

Please or to buy this product.
  • SKU
    0576-41-07/0576/07

STORAGE
The gloves must be kept in their original wrapping. Do not compress them. Do not fold them. Do not store them near light or heat sources natural or artificial . Storage temperature must be between 10 and 21° C. Humidity 60+/- 10%

TRANSPORT
Transport conditions must be the same as storage conditions

PRECAUTIONS
Gloves should now be allowed unnecessarily to come in contact with oil, grease, turpentine, white spirit, strong acid or any corrosive products. Do not use wet gloves

USE
Inflate the gloves with air in order to detect potential faults. Carry out visual inspection. The standards EN 60903 and IEC 60903 indicate in annex E.3 (informative) that Category C should be used in ambient temperatures between -40° C and +55° C

CLEANING
With water and soft soap only . Dry at less than 65° C.

SPECIAL PROPERTIES
· CATEGORY H (oil resistance)
Conditioning of gloves by immersion for 24 hr in oil (liquid 102) at 70 ± 2 °C:
Proof and withstand test voltage
Mechanical resistance : > 50% of non conditioning gloves
· CATEGORY A (resistance to acid)
Conditioning of gloves by immersion for 8 hr in sulphuric acid solution (32° Be) heated at 23 ± 2 °C:
Proof and withstand test voltage
Mechanical resistance : > 75% of non conditioning gloves
· CATEGORY Z (resistance to ozone)
Conditioning of gloves for 3 hr in a chamber at 40 ± 2 °C and in a 1 ± 0.01 mg/m3 ozone concentration
Visual control
Proof and withstand test voltage
· CATEGORY C : (resistance to very low temperatures)
Conditioning of gloves for 24 hr at -40 ± 3 °C. and then shall be folded at the wrist in order to be placed between two
polyethylene plate and being subjected to a force of 100 N for 30 seconds :
Visual control
Proof and withstand test voltage
· CATEGORY R = A + Z + H

PACKING :
Each pair of gloves is packaged in an opaque sachet with a direction of use inside. On the packaging, the following information is given : class, size, categories, type of cuff, length of gloves, test date, manufacture and validation batch numbers. The sachet and instruction for use are certified as part of the PPE and must be kept with the gloves.

  • Class Voltage (V)
    2
  • Length (mm)
    410
  • Material
    Natural Rubber Latex (Composite)
  • Maximum Working Voltage (V)
    17000
  • Sizes Available
    7
  • Thickness (mm)
    3.1
  • Test Voltage (V)
    20000
  • Manufacturer
    Boddingtons Electrical Ltd

Boddingtons Electrical Ltd partner with TNT for our UK consignments. Should you wish for your orders to have shipping notifications you can advise of an email address that we can add to the TNT shipping software to initiate this for your account.

TNT Tracking 

https://www.tnt.com/express/en_gb/site/shipping-tools/tracking.html 

Cut-Off Times

Purchase order placed before 3pm with the item ex-stock can be processed for same day shipment. We do have the flexibility to process orders at a later time but please check with customer services . 

UK Services

  • Standard - 2-3 working days
  • Express - Next-day delivery - by end of business day
  • 12:00 - Next-day delivery - guaranteed by noon
  • 10:00 - Next-day delivery - guaranteed by 10am
  • 9:00 - Next-day delivery - guaranteed by 9am

Minimum Order Value

The minimum order value for carriage paid orders is £250.00 (nett) excluding vat.
Carriage paid orders exclude Timed Services such as 9am/10am/Noon.
We do not have a minimum order value however a carriage charge will be applied depending on the service level chosen.  

Heavier/Dimensional/Large Items - Matting/Cable Guard/StayWire/BodTech 

'Heavier items' including some of the above will incur a shipping charge of £15.00 excluding vat due to there size/dimensions/weight.



EN 60903 - Live working - Electrical insulating gloves

EN 60903:2003 - Gloves and mitts of insulating material for live working, corrected 2004 and 2006.

This European Standard specifies the requirements and test methods for gloves and wiring gloves intended for use by workers exposed to high-tension electrical voltage. This standard and does not make reference to other glove standards, such as EN 420 (general requirements), EN 388 (mechanical risks), or EN 374 (chemical risks).

Gloves that are manufactured and certified according to EN standard 60903 are the only gloves that should be used when there is a risk of electrical shock. To help determine which gloves provide the best protection, it is important to know gloves’ capacities relative to different voltage levels.

To limit the effects of wear and tear (e.g., contact with sharp cables), specially designed protective gloves can and should be worn over electrical insulating gloves.

 

ClassTested atWorking voltage
002.500V500V
05.000V1.000V
110.000V7.000V
220.000V17.000V
330.000V26.000V
440.000V36.000V

 

Optional:

Category optionalAdditional requirements
AAcid resistance
HOil resistance
ZOzone resistance
MResistance against high mechanical strain
RResistance against acid, oil, ozone, and high mechanical strain
CResistance against extreme cold

 

Insulating protective gloves require inspections every 6 months and should be subjected to the following:

Classes 00 and 0 – examination to detect air leaks and visual inspection

Classes 1 to 4 – examination to detect air leaks, visual inspection, and electrical test

  • Power Maintenance, Repair and Transmission
    • HVMSB - High Voltage Main Switchboard
    • HVCSB - High Voltage Circuit Breaker
    • LVSB - Low Voltage Switchboard
    • LVCSB - Low Voltage Circuit Breaker
    • LVMSB - Low Voltage Main Switchboard
    • EMSB - Electrical Main Switchboard/Emergency Main Switchboard
  • Electrical Contractors
  • Hybrid Engine Manufacturing and Repair
  • Mass Transit Repair and Maintenance
  • Telecome repair near electrical wires




Related products

Drop items here to shop
Product has been added to your cart