Standards

NF EN 50321-1:2018 ASTM 1117, ASTM 2413, ASTM F26121:2019, EN 13287, EN ISO 20345
ST HTA 70 B (RTE SERECT)

An electrically insulating Class 2 dielectric boot with an integral steel toe cap and vulcanized rubber sole for superior slip resistance. The class 2  Dielectric boot provides high voltage protection of up to 20kV over the complete boot for over 8 hours, and 35kV over the sole for 3 minutes. This high-voltage boot is suitable for use by electricians, utility engineers and live working up to 17kV

Please or to buy this product.
SKU Sizes Available Operating Voltage AC Operating Voltage DC ATPV (Cal/Cm²) Class Category Pack Size Each Weight (g)
Thumbnail MV-137/36 European Size 36 17 000 V 25 500 V 40 2 SRC Each 2200
Thumbnail MV-137/37 European Size 37 17 000 V 25 500 V 40 2 SRC Each 2300
Thumbnail MV-137/39 European Size 39 17 000 V 25 500 V 40 2 SRC Each 2400
Thumbnail MV-137/41 European Size 41 17 000 V 25 500 V 40 2 SRC Each 2200
Thumbnail MV-137/42 European Size 42 17 000 V 25 500 V 40 2 SRC Each 2600
Thumbnail MV-137/43 European Size 43 17 000 V 25 500 V 40 2 SRC Each 2650
Thumbnail MV-137/44 European Size 44 17 000 V 25 500 V 40 2 SRC Each 2850
Thumbnail MV-137/45 European Size 45 17 000 V 25 500 V 40 2 SRC Each 3000
Thumbnail MV-137/46 European Size 46 17 000 V 25 500 V 40 2 SRC Each 3200
Thumbnail MV-137/47 European Size 47 17 000 V 25 500 V 40 2 SRC Each 3200
Thumbnail MV-137/48 European Size 48 17 000 V 25 500 V 40 2 SRC Each 3700
Feature
Feature



Feature
Feature



Feature
Feature



Feature
Feature



Feature




Product Features

  • 200 Joule epoxy coated steel toe cap (soft toe version also available)
  • Heat resistant sole EN 20345:2012 HRO, 60 seconds at 300°C
  • Cold insulation to EN ISO 20345:2012 CI
  • Fuel and oil-resistant sole
  • Vulcanized rubber sole for improved slip resistance - 30% better than a conventional safety boot sole
  • Durable, cut-resistant vulcanised rubber sole, significantly extends the working life, even in harsh terrain
  • Cleated outsole for maximum grip in wet and oily conditions (SRC)
  • Energy absorbing tunnel system in the heel to EN 20345:2011 E
  • Injection moulded using our proprietary Dielectric compound for a seamless boot with excellent electrical insulation properties
  • Non-wicking knitted nylon lining
  • Step voltage protection up to 35kV
  • Arc flash protection – Meets the requirements of ASTM F2621-2019 at 40Cal/cm²
  • Ergonomic cushioned insole (removable & machine washable) for greater wearer comfort
  • Kick-off lug
  • Adjustable height
  • CE marked on the shaft with date and year of manufacture
  • REACH Compliant
  • Machine washable at up to 40°C
  • Shelf life of over 10 years
    • Each Weight (g)
      2200 g
    • SKU
      MV-137/36
    • EAN
      3597560071764
    • HS Commodity Codes
      64029110
  • Manufacturer
    CATU SAS is a subsidiary of the SICAME Group
  • Country of Origin
    France
  • Sizes Available
    European Size 36, European Size 37, European Size 39, European Size 41, European Size 42, European Size 43, European Size 44, European Size 45, European Size 46, European Size 47, European Size 48
  • Operating Voltage AC
    17 000 V, Not Applicable
  • Operating Voltage DC
    25 500 V, Not Applicable
  • ATPV (Cal/Cm²)
    40, Not Applicable
  • Class
    2, Not Applicable
  • Category
    SRC, Not Applicable
  • Pack Size
    Each, 5

Tags 

EN 50321-1:2018 is the new standard for insulating footwear for live working and was published earlier this year, it replaces EN 50321:1999 and is currently out for approval as an IEC standard which will make it a global standard, not just European.

The main changes in the 2018 revision are the introduction of new 4 classes (see below) for working up to 36 KV (the old standard only went up to Class 0 - 1 KV). Boots are now tested by filling with water instead of ball bearings to simulate water or perspiration potentiality wicking up the lining and creating a flash over. There is also now an electrical test after perforation of the sole by a nail, to ensure boots still give electrical protection after perforation. Even non-metallic perforation inserts can allow water to pass through them so will allow an electrical current to pass when the sole is punctured. The table below lists the classes and the test requirements:

Class RatingMaximum Working VoltageWithstand Test VoltageLeakage Current Test VoltageMaximum Leakage Current
Class 00500V5kV2.5kV3mA
Class 01kV10kV5kV5mA (8mA)
Class 17.5kV20kV10kV10mA (16mA)
Class 217.5kV30kV20kV18mA
Class 326.5kV40kV30kV20mA
Class 436kV50kV40kV24mA

(Overboot requirements are in brackets where they are different from knee high boots)