CATU MS-918 Low Voltage Detector DETEX , Proving Unit with Phase Rotation

Score: 5.00 (votes: 1)
No reviews.
Please or to buy this product.
SKU Features Operating Voltage AC Carry Bag Included Weight
Thumbnail MS918PG Fitted with IP2X Test Lead Points with Retractable Trigger Tips. 12 - 900 V No 270
Thumbnail MS918 Fitted with IP2X Test Lead Points with Retractable Sleeves. 12 - 900 V No 210
Thumbnail MS918ET Fitted with IP2X Test Lead Points with Retractable Sleeves. 12 - 900 V Yes 350
MS-918-PGMS-918MS-918-ET

icons-france.png

UKCA.png

CE-0.png

Double-triangle.jpeg

Standards

IEC 61243-3:2014 / NF EN 61243-3:2015 / NF C18-510 / EN 50110-1 / IEC 61010-1 / IEC 61010-031 / GS38 (2015)

Low Voltage detector DETEX


Application:

  • Check the presence of voltage. 
  • Checks voltage levels from 12 to 900 V AC, 12 to 1 000 V DC.
  • Sound and light continuity for a non-live circuit (threshold of 80 Ω).
  • Search for the polarities of a DC circuit. 
  • Unipolar phase identification. 
  • Phase rotation detection check (two-wire method).
  • For indoor / outdoor use. 


Features:

  • Fitted with IP2X test lead points with retractable trigger tips.
  • Total safety with hazardous voltage indicator light (> 50 V).
  • Protection level: IP65/IK06.
  • Self test button to discern the verification of the good functioning and the continuity function. 
  • Completely modular and adjustable to eclipse sockets. 
  • Equipped with a lighting lamp at the measuring point. 
  • LED display.


Composition:

  • Supplied with soft carrying case and belt loop Ref. M-87285.


Optional accessories: 

  • 2 test plug adapters to be fixed on IP2X test lead points with retractable trigger tips enabling to target test plugs Ø 4 mm. Ref. DX-04
  • Holder, Ref. M-952325.
  • Contact probes for L.V. detectors for installation and sidewalk boxes. Ref. M-8013.
  • Contact probes for L.V. detectors for flight path. Ref. M-8014.
  • Hand stick & stick extension. Ref. M-951143.

icons-france.png

UKCA.png

CE-0.png

Double-triangle.jpeg

Standards

IEC 61243-3:2014 / NF EN 61243-3:2015 / NF C18-510 / EN 50110-1 / IEC 61010-1 / IEC 61010-031 / GS38 (2015)

Low Voltage detector DETEX


Application:

  • Check the presence of voltage. 
  • Checks voltage levels from 12 to 900 V AC, 12 to 1 000 V DC (according to models).
  • Sound and light continuity for a non-live circuit (threshold of 80 Ω).
  • Search for the polarities of a DC circuit. 
  • Unipolar phase identification. 
  • Phase rotation detection check (two-wire method).
  • For indoor / outdoor use. 


Features:

  • Fitted with IP2X test lead points with retractable sleeves.
  • Total safety with hazardous voltage indicator light (> 50 V).
  • Protection level: IP65/IK06.
  • Self test button to discern the verification of the good functioning and the continuity function. 
  • Completely modular and adjustable to eclipse sockets. 
  • Equipped with a lighting lamp at the measuring point. 
  • LED display.


Optional accessories: 

  • 2 test plug adapters to be fixed on IP2X test lead points with retractable trigger tips enabling to target test plugs Ø 4 mm. Ref. DX-04
  • Carrying bag with belt loop, Ref. M-87285.
  • Holder, Ref. M-952325.
  • Contact probes for L.V. detectors for installation and sidewalk boxes. Ref. M-8013.
  • Contact probes for L.V. detectors for flight path. Ref. M-8014.
  • Hand stick & stick extension. Ref. M-951143.

icons-france.png

UKCA.png

CE-0.png

Double-triangle.jpeg

Standards

IEC 61243-3:2014 / NF EN 61243-3:2015 / NF C18-510 / EN 50110-1 / IEC 61010-1 / IEC 61010-031 / GS38 (2015)

Low Voltage detector DETEX


Application:

  • Check the presence of voltage. 
  • Checks voltage levels from 12 to 900 V AC, 12 to 1 000 V DC (according to models).
  • Sound and light continuity for a non-live circuit (threshold of 80 Ω).
  • Search for the polarities of a DC circuit. 
  • Unipolar phase identification. 
  • Phase rotation detection check (two-wire method).
  • For indoor / outdoor use. 


Features:

  • Fitted with IP2X test lead points with retractable sleeves.
  • Total safety with hazardous voltage indicator light (> 50 V).
  • Protection level: IP65/IK06.
  • Self test button to discern the verification of the good functioning and the continuity function. 
  • Completely modular and adjustable to eclipse sockets. 
  • Equipped with a lighting lamp at the measuring point. 
  • LED display. 


Composition:

  • Supplied with soft carrying case and belt loop Ref. M-87285.


Optional accessories: 

  • Holder, Ref. M-952325.
  • Contact probes for L.V. detectors for installation and sidewalk boxes. Ref. M-8013.
  • Contact probes for L.V. detectors for flight path. Ref. M-8014.
  • Hand stick & stick extension. Ref. M-951143.

    • Weight
      270 g
    • SKU
      MS918PG
    • EAN
      3597560059045
    • HS Commodity Codes
      90303370
  • Manufacturer
    CATU SAS is a subsidiary of the SICAME Group
  • Country of Origin
    France
  • Features
    Fitted with IP2X Test Lead Points with Retractable Trigger Tips., Fitted with IP2X Test Lead Points with Retractable Sleeves.
  • Operating Voltage AC
    12 - 900 V, Not Applicable